Go back
Danfoss Timeswitch Conversions
 
Manufacturer Model
Replacement
Wallplate connections and function
Compatible with existing wall plates.
Earth
Neutral
Live
Com
Off
Spare
On
   
E
N
L
1
2
3
4
   
Use same wallplate.
Danfoss Randall TS15 & TS715
TS715
E
N
L
1
2
3
4
   
Horstmann C11 & C17
TS715
2
3
 
4
   
Sunvic (Peglar) Select 107
TS715
1
2
4
3
   
Manufacturer Model
Replacement
Wallplate connections and function
Compatible with existing wall plates. Simple wiring changes required.
Earth
Neutral
Live
Com
Off
Spare
On
   
E
N
L
1
2
3
4
   
Use same wallplate, No wiring changes needed.
Invensys (ACL,Drayton) LP111,LP711,LS111,LS711,Tempus1 & Tempus 2.
TS715
 
N
L
1
2
4
3
   
Invensys (Switchmaster) 300
TS715
4
   
1
   
Siemens (Landis & Staefa) RWB100,RWB152,RWB170,RWB3,RWB30,RWB50 &RWB7
TS715
2
3
 
4
   
Manufacturer Model
Replacement
Wallplate connections and function
New wallplate needed. Wiring changes needed.
Earth
Neutral
Live
Com
Off
Spare
On
   
E
N
L
1
2
3
4
   
Use same wallplate, Wiring changes needed.
Danfoss Randall 701
TS715
E
N
L
 
3
1
     
Danfoss Randall 103, 103E, 103E5, 103E7
TS975
5
6
3
   
1
   
Grasslin (Towerchron) QE1
TS715
N
L
2
3
 
4
   
Grasslin (Towerchron) T2001 & T2001Q
TS715
N
L
     
7
   
Honeywell ST6100A & ST6100C
TS715
N
L
1
2
 
4
   
Horstmann CENTAUR SC1 & SC7
TS715
N
L
4
   
3
   
Horstmann CORONET, 517, H11, H17
TS715
N
L
5
6
 
4
   
Invensys (ACL,Drayton) TEMPUS 1, TEMPUS 2 (OLD MODELS)
TS715
N
L
1
3
4
2
   
Potterton(Potterton Myson) EP4001, EP4002 & EP5002
TS715
N
L
5
2
 
4
   
Sunvic (Pegler Sunvic) SP20 & SP35
TS715
N
L
3
4
 
5
   
Manufacturer Model
Replacement
Wallplate connections and function
TS975 Replacement Programmer fits directly to SET (British Gas) wallplates.
No need to replace wall plate or rewire - set TS975 in MK9 Mode.
Earth
Neutral
Live
Com
Off
Spare
On
Com
On
E
N
L
1
2
3
4
5
6
For mains voltage link terminal L to terminal 5
Danfoss Randall 911 & 971 (MK9 Mode)
TS975
E
N
L
     
4
5
6
Danfoss Randall 971
TS975
Manufacturer Model
Replacement
Wallplate connections and function
TS975 Replacement Programmer fits directly to SET (British Gas) wallplates.
No need to replace wall plate or rewire - set TS975 in SET Mode.
Earth
Neutral
Live
Com
Off
Spare
On
Com
Off
E
N
L
1
2
3
4
5
6
For mains voltage link terminal L to terminal 5
Danfoss Randall SET 1, SET 1E, SET 4 (SET MODE)
TS975
E
N
L
     
4
5
6
Horstmann 517, CORONET & 423
TS975
Manufacturer Model
Replacement
Wallplate connections and function
Compatible with existing wallplates, no re-wiring necessary.
Earth
Neutral
Live
HW off
CH off
HW on
CH on
   
E
N
L
1
2
3
4
   
Use same wallplate, No wiring changes needed.
Danfoss Randall CP16, CP75, MP15, MP75,FP15 & FP75
FP715
E
N
L
1
2
3
4
   
Glowworm Mastermind
FP715
Grasslin (Towerchron) DP72 & QE2
FP715
Horstmann C21 & C27
FP715
Invensys LP112,LP241,LP522,LS241,LS522,LS722,Tempus 6 & 7
FP715
Siemens RWB102,RWB2,RWB2.9,RWB20,RWB200,RWB252,RWB270,RWB40 & RWB9
FP715
Manufacturer Model
Replacement
Wallplate connections and function (New wallplate)
New wallplate needed (Supplied with new clock), mark existing wires and reconnect according to table left.
Earth
Neutral
Live
HW off
CH Off
HW on
CH on
   
E
N
L
1
2
3
4
   
Re-wire as below. Link as instructed.
Danfoss Randall 702
CP715
E
N
L
4
2
3
1
   
Danfoss Randall 102, 102E, 102E5 & 102E7 (Link 6 - 3)
CP715
5
6
   
1
2
   
Danfoss Randall 3020P, 3060 & 4033
CP715
7
6
   
4
2
   
Danfoss Randall 4033 (Link 6 - 1)
CP715
N
L
5
3
4
2
   
Grasslin (Towerchron) QE2
FP715
N
L
1
2
3
4
   
Honeywell ST6200A, ST6300A, ST6400C & ST6450
CP715
N
L
1
2
3
4
   
Honeywell ST699B & ST799A1003
CP715
N
L
7
4
6
3
   
Invensys (ACL Drayton) Tempus 3, 4, 6 & 7 (Old models)
CP715
N
L
1
2
3
4
   
Invensys (ACL Drayton) Switchmaster 400 & 600 (No terminal 4 on 600)
CP715
N
L
 
4
3
1
   
Invensys (ACL Drayton) Switchmaster 805, 900, 905 & 9001
CP715
N
L
4
2
3
1
   
Potterton EP2000, 2001, 2002, 3001, 3002, 6000 & 6002
CP715
N
L
1
2
3
4
   
Sunvic (Pegler Sunvic) SP100, SP25, SP30 & SP50
FP715
N
L
1
4
2
5
   
Grasslin (Towerchron) MP
CP715
2
1
   
6
10
   
Grasslin (Towerchron) FP
CP715
2
1
8
11
6
10
   
Manufacturer Model
Replacement
Existing MK9 wallplate, set programmer to MK9 mode.
FP975 replacement programmer, Fits directly to MK9 wallplates. No rewiring needed.Set FP975 in MK9 mode.
Earth
Neutral
Live
HW off
HW com
HW on
CH off
CH com
CH on
E
N
L
1
2
3
4
5
6
Link terminal L to terminals 2 & 5
Danfoss Randall 922 & 972 (MK9 model), link L-5 & 2
FP975
E
N
L
1
2
3
4
5
6
Manufacturer Model
Replacement
Existing SET/British Gas wallplate, set to SET mode
FP975 replacement programmer, Fits directly to SET (British Gas) wallplates. No rewiring needed.
Earth
Neutral
Live
HW on
HW com
HW off
CH on
CH com
CH off
E
N
L
1
2
3
4
5
6
Link terminal L to terminals 2 & 5
Danfoss Randall SET4, SET5, SET3E & SET3M
FP975
E
N
L
1
2
3
4
5
6
Danfoss Randall